Dairy Pasteurization PHE Supply

HTST pasteurization (72–75 ℃ / 15 s) is the core process of fresh-milk production. This project supplied SAMIT sanitary-grade three-stage plate heat exchangers for a 200 t/d fresh-milk line of a North China dairy group, paired with a fully automatic CIP (Clean-in-Place) system.

1. Project Background

Customer

A well-known North China dairy group; newly built 200 t/d fresh pasteurized-milk line, required to meet EU hygiene standards.

Process Requirements

Raw milk 4 ℃ → preheat 65 ℃ → pasteurize 75 ℃ × 15 s → cool 4 ℃ → aseptic filling.

Key Constraints

  • Ra ≤ 0.4 μm, dead-leg-free design
  • FDA / 3-A / cGMP certification
  • Daily automatic CIP

2. Technical Solution

The SAMIT S-series sanitary plate heat exchanger was adopted, arranged in three stages for heat recovery. Plates are 316L stainless steel, electropolished to Ra 0.38 μm; seals are FDA-compliant EPDM, and all end-plate ports use tri-clamp fittings.

StageFunctionHot Side (Milk)Cold SideArea
Preheat (Heat Recovery)Cold milk ↔ freshly pasteurized hot milk75 → 20 ℃4 → 65 ℃32 m²
PasteurizationHeated by hot water to pasteurization temp.65 → 75 ℃78 → 73 ℃ hot water6 m²
CoolingChilled water cools heat-recovered milk to 4 ℃20 → 4 ℃1.5 → 6 ℃ chilled water12 m²
TotalThree-stage heat-recovery rate 92%50 m²

3. Process Flow

Three-stage HTST Pasteurization Heat Recovery Flow Raw Milk 4 ℃ Preheat (Heat Recovery) 4 ℃ → 65 ℃ Area 32 m² Pasteurization 65 ℃ → 75 ℃ ×15 s Area 6 m² Cooling 20 ℃ → 4 ℃ Area 12 m² Aseptic Filling 4 ℃ finished milk 75 ℃ hot milk returns to preheat cold milk (core of heat recovery) Heat recovery 92% · Steam consumption only 1/8 of conventional · Daily automatic CIP 316L electropolished Ra 0.38 μm · FDA / 3-A certified · Tri-clamp, dead-leg-free

4. Implementation

  • Equipment supply: 1 set of sanitary PHE + 1 CIP (Clean-in-Place) system + 1 automation control cabinet.
  • Key quality: All wetted parts electropolished to Ra 0.38 μm; gaskets supplied with FDA 21 CFR 177.2600 compliance certificate; the whole unit passed 3-A certification.
  • Installation & commissioning: 30-day on-site installation + 7-day performance test; pasteurization-stage temperature accuracy ±0.3 ℃.

Differentiated design: The corner-port gaskets of SAMIT sanitary PHEs feature a "leak-off groove"; should a gasket fail, the medium drains visibly through the groove, preventing cold/hot milk cross-mixing and batch contamination. This is a safety feature absent from ordinary industrial-grade PHEs.

5. Operating Results

Energy Saving

92% heat-recovery rate; saves 1800 t/year of steam, equivalent to 165 t of standard coal.

Product Quality

Pasteurization temperature accuracy ±0.3 ℃; total plate count ≤ 5000 CFU/mL, better than the national standard.

Hygiene Performance

Post-CIP microbial test 0 CFU/mL; plates still bright as new after a 3-year opening inspection.

6. Lessons Learned

The core of dairy pasteurization is the heat-recovery rate. Every 1-percentage-point increase saves 50,000–80,000 RMB/year in steam cost (at 200 t/d scale). The SAMIT three-stage design reaches 92% heat recovery — industry-leading. We advise dairies not to look only at first cost when selecting, but to focus on the 5-year total cost (including steam consumption and spare parts).